The most important spares—overview, Chimney fire, Gaskets – Austroflamm Wien User Manual
Page 8: Other parts, Accessories, Maintenance, Cleaning, Important

Wien
6 english
Chimney fire
A Chimney fire may occur, due to sooting and
deposits in the chimney, if wrong or humid fuel is
used. Close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have
an expert inspect your chimney for cracks and air-
tightness after the burning out of the chimney.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description Part
number
Flat gasket 8 x 2; L = 1220 mm
710096
Round gasket
∅8 ; L = 1680 mm
710049
Other parts
Description
Nr. drawing
Part number
Bottom plate
1
717108-29
Grate 2
784004
Bottom keramott
3
717103
Rear keramott
4
717102
Side left keramott
5
717105
Rear keramott
6
717104
Wood retainer keramott
7
717101
Baffle plate keramott
8
717106
Description Part
number
WIEN door glass
716002
Stove lacquer
650002
Glass cleaner ½ litre
640070
Accessories
You can obtain floor plates made of glass or steel, hearth accessories or care products from your certified
dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer only. This will guarantee that your
stove functions properly and safely.
The fireplace must not be amended.
Maintenance
To clean the glass, please use a specialized product such as Thermohit glass cleaner. Lacquered
surfaces are to be cleaned only with a cloth (may be damp). Special cleaning agents should also be used
for stainless steel surfaces.
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if
necessary more often, e.g. after the cleaning of the chimney. The chimney also has to be cleaned
regularly by the chimneysweeper. Your chimneysweeper will inform you of the necessary inspection
intervals. An expert should inspect the stove annually.