The most important spares—overview, Heating in-between seasons, Chimney fire – Austroflamm Uno Back User Manual
Page 9: Gaskets, Keramott, Other parts

english
7 Uno
Back
Fig. 4:
adjust air lever
 
The grate does not have to be operated during 
operation. It is only used for moving ashes from the 
combustion chamber to the ash box, when stove is 
not in operation. 
Heating in-between seasons
If you heat the stove in between seasons, when the 
outside temperatures are higher, the flue gases may 
not be able to escape completely and this may lead to 
disturbances in the chimney draught, especially if the 
temperatures are rising suddenly. The stove has to 
be charged with less wood then and the primary air 
has to be increased so that the wood can burn down 
faster (with visible flames) and thus the chimney 
draught can stabilize. 
 
 
Chimney fire
A chimney fire may occur, due to sooting and 
deposits in the chimney, if wrong or humid fuel is 
used. In case of a chimney fire close all air inlets on 
the fireplace/chimney immediately and call the fire 
brigade. Please have an expert inspect your chimney 
for cracks and air-tightness after the burning out of 
the chimney. 
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description Nr.drawing Part
number
Gasket round Ø6, L=1700 mm
10
710696
Gasket round Ø14, L=1900 mm
11
714223
 
Keramott 
Description Nr.drawing Part
number
Bottom left, Keramott
1
717911
Bottom right, Keramott
2
717912
Wood retainer, Keramott
3
717917
Rear, Keramott
4
717913
Side component left, Keramott
5
717914
Side component right, Keramott
6
717915
Baffle plate rear, Keramott
7
717916
Grate
8
712064
Riddling grate
9
716122
 
 
Other parts 
Description Nr.drawing Part
number
Uno Back door
12
717901
Door handle
13
717900
Uno Back door glass
14
717862
Baking compartment
15
719098
Baking compartment handle
16
719092-18
Baking compartment glass
17
719083
Glass cleaner ½ litre
--
640070
Stove lacquer
--
650002
 
 
 
 
 
 
Keramott numbering = installation instructions!