Eriodic, Aintenance – Dansons V-50 User Manual
Page 34
Can
adian Comfort Industries V05
34
VULCAN “V” SERIES OWNERS MANUAL
Copyright 2005
www.salesunlimited.com
Dansons Group Inc.
P
ERIODIC
M
AINTENANCE
…
CONTINUED
INSPECT AND CLEAN THE CHIMNEY:
[ELECTRICAL CORD UNPLUGGED] Under some
conditions fly ash build up in the chimney system may occur rapidly. The fly ash will collect in the exhaust
venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during
startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will
collect in the exhaust venting system. Check the clean out tees and elbows in the exhaust system
periodically to determine the cleaning schedule. To remove dust from the vent pipe, tap lightly on the pipe to
dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of
the vent pipe as possible. 3 or 4-inch chimney brushes are available for chimney cleaning. If the exhaust
system has a screen on it, frequently clean the screen. A plugged screen will shut off combustion air and
cause a fire to die or burn poorly.
PAINTED SURFACES:
Painted surfaces may be wiped down with a damp cloth. If scratches appear or
you wish to renew your paint, contact your Dealer to obtain a can of Satin Black (“Stove Bright”) paint.
Tip: use a hair dryer to warm the surface prior to touching up the paint,
this helps to reduce paint runs.
Note: Do not use any other brand than “Stove Bright” as they may not be compatible.
FALL START UP:
Prior to lighting the first fire check the outside area around the exhaust and air intake
systems for obstructions. Clean the screens on the exhaust system and the outside air intake pipe. Turn all
controls on to make sure they are working prior to lighting the first fire. Clean and remove fly ash from
exhaust venting. Your local Authorized Dealer should have 3” and 4” chimney brushes available. This is
also a good time to give the entire stove a good cleaning throughout.
SPRING SHUTDOWN:
[COLD STOVE AND COLD ASHES ONLY]. After the last burn in the spring
remove pellets from the hopper and the auger. Scoop out the pellets then run the auger until the hopper is
empty and pellets stop flowing. Vacuum out the hopper. Thoroughly clean the burn grate, burn box, ashtray
and ash traps. It’s desirable to spray the inside of the cleaned hopper with an aerosol silicone spray if your
stove is in a high humidity area. The
exhaust system should be thoroughly cleaned.
YEARLY SERVICING:
A yearly servicing and cleaning by your Authorized VULCAN “V” SERIES
Dealer is recommended. A fee may be charged for this service.
Figure 30
Window
Burn Pot
Heat Tubes
Tube Scraper
“Super”
Grate
Hopper
Fan Motors
Auger
Exhaust
Air Intake
Auger Motor
(Optional)
Pedestal