beautypg.com

Maintenance – American Sanders B-2+ Edger User Manual

Page 10

background image

- 10 -

Clarke

®

American Sanders

Operator's Manual (CE) - American B-2

MAINTENANCE

CAUTION: Maintenance and repairs performed by

unauthorized personnel could result

in damage or injury. Maintenance

and repairs performed by unauthor-

ized personnel will void your warranty.

Servicing of these units must always be

referred to an authorized Clarke Ameri-

can Sanders distributor.

The Dust Control System

Remove the dust from the bag when the bag is

1

/

3

full or when the efficiency of the dust control system

decreases.

If the exhaust pipe gets an obstruction, follow this proce-

dure:

1. Remove the four screws that hold the exhaust

pipe to the housing. See figure 5.

2. Remove the obstruction from the exhaust pipe.

3. Install the exhaust pipe.

How to Adjust the Angle Of The Sandpaper Disc To

The Floor

The adjustment of the machine is correct when the front

part of the sandpaper disc makes contact with the floor.

To change the adjustment of the machine, follow

this procedure:

1. Using the special wrench, loosen the lock nut on

each caster. See (1) figure 6.1.

2. Loosen the jam nut. See (2) figure 6.2.

3. Raise or lower the casters as needed.

4. Tighten the jam nut on each caster.

5. Tighten the lock nut on each caster.

The Ventilation Plug

1. To clean the ventilation opening in the center of

the plug, remove the plug from the machine. With

the plug removed, also inspect the grease in the

gearbox. See figure 7.

Figure 5

Figure 7

Figure 6