14
© 2008 Directed Electronics All rights reserved
the light goes out, however, the doors are monitored normally 3-sec-
onds later.
Disarming diagnostics
Extra disarm horn honks are the tamper alert. If four short horn honks
are heard when disarming, the system was triggered in your absence.
If five short horn honks are heard, a zone was triggered so many times
that false alarm prevention circuitry has bypassed that zone. In either
case, the status LED will indicate which zone was involved (see Table of
Zones below). The system will retain this information in its memory, and
the horn honks four or five times each time it is disarmed, until the next
time the ignition key is turned on.
Table of zones
The zone number is the number of LED flashes used by the system to
identify that input. The standard input assignments are listed below.
ZONE
(Number
LED Flashes)
DESCRIPTION
1
Instant trigger - often used
for hood/trunk pin switches
2
Heavy impact from onboard Doubleguard shock
sensor
3
Door switch trigger
4
Optional sensor
5
Ignition trigger
The LED will not report if the Warn Away response is triggered.