ADLINK Express-CB User Manual
Page 58
Express-CB User’s Manual
Page 58
Console Redirection Settings (cont’d)
Terminal Type
VT-UTF8 is the preferred terminal type for out-of-band management. The next best choice is
VT100+ and then VT100. Configuration options: VT100, VT100+, VT-UTF8, ASNI.
Bits per second
Select the bits per second you want the serial port to use for console redirection. The
options are 115200 ,57600 ,19200, 9600.
Data Bits
Select the data bits you want the serial port to use for console redirection. Set this value to 7
or 8.
Parity
Set this option to select parity for console redirection. The settings for this value are None,
Even, Odd, Mark and Space.
Stop Bits
Stop bits indicate the end of a serial data packet. The standard setting is 1 stop bit.
Communication with slow devices may require more than 1 stop bit. Set this value to 1 or 2.
Flow Control
Set this option to select Flow Control for console redirection. The settings for this value are
None, Hardware and Software.
Terminal Resolution
Remote Terminal Resolution. Set this value to 80x25 or 100x31.