ADLINK ASD25-SLC Series User Manual
Page 10

10
User's Manual
1.2.15. Electromagnetic Immunity
Electromagnetic Immunity tests assume the SSD is properly installed in the representative host system. The
drive operates properly without errors degradation in performance when subjected to radio frequency (RF)
environments defined in the following table.
Test
Description
Performance criteria Reference standard
Electrostatic discharge
Contact, HCP, VCP: ±8KV
Air: ±15KV
B
EN 61000‐4‐2:95
Radiated RF immunity
80~1000MHz, 3V/m,
80% AM with 1 KHz sine
900 MHz, 3 V/m, 50%
pulse modulation at
200Hz
A
EN 61000‐4‐3:96
ENV 50204:95
Electrical fast transient
±1KV on AC mains
±0.5KV on external I/O
B
EN 61000‐4‐4:95
Surge immunity
±1KV differential ±2KV
common, AC mains
B
EN 61000‐4‐5:95
Conducted RF immunity
150KHz~80 MHz, 3 Vrms,
80% AM with 1KHz sine
A
EN 61000‐4‐6:97
Voltage dips, interrupts
0% open, 5 sec
0% short, 5 sec
40%, 0.10 sec
70%, 0.01 sec
C
C
C
B
EN 61000‐4‐11:94
Table 12: Radio Frequency Specifications
Notes:
1. Performance criterion A = The device shall continue to operate as intended, i.e., normal
unit operation with no degradation of performance.
2. Performance criterion B = The device shall continue to operate as intended after
completion of test, however, during the test, some degradation of performance is allowed
as long as there is no data loss operator intervention to restore device function.
3. Performance criterion C = Temporary loss of function is allowed. Operator intervention is
acceptable to restore device function.
4. Contact electrostatic discharge is applied to drive enclosure.
1.2.16. Weight: 80 g Max ( with case )
1.2.17. Dimension: 100.0mm x 69.8mm x 9.5 mm (L x W x H)
1.2.18. Part Numbers:
Part No.
Product Name
Temperature
92‐99059‐0210
ASD25‐SLC32G‐ET
‐40°C~+85°C
92‐99059‐0010
ASD25‐SLC64G‐ET
‐40°C~+85°C
92‐99059‐0110
ASD25‐SLC128G‐ET
‐40°C~+85°C
92‐99059‐0310
ASD25‐SLC32G‐CT
0°C~+70°C
92‐99059‐1010
ASD25‐SLC64G‐CT
0°C~+70°C
92‐99059‐2010
ASD25‐SLC128G‐CT
0°C~+70°C