Subcommand

Code

LBA Low value

SMART ATTRIBUTE VALUES (READ DATA)

D0h

READ ATTRIBUTE THRESHOLDS

D1h

ENABLE/DISABLE ATTRIBUTE AUTOSAVE

D2h

SAVE ATTRIBUTE VALUES

D3h

EXECUTE OFF-LINE IMMEDIATE

D4h

EXECUTE SMART OFF-LINE ROUTINE

00h

EXECUTE SMART SHORT SELF-TEST ROUTINE (OFFLINE)

01h

EXECUTE SMART EXTENDED SELF-TEST ROUTINE (OFFLINE)

02h

ABORT OFF-LINE ROUTINE

7Fh

EXECUTE SMART SHORT SELF-TEST ROUTINE (CAPTIVE)

81h

EXECUTE SMART EXTENDED SELF-TEST ROUTINE (CAPTIVE)

82h

READ LOG SECTOR

D5h

WRITE LOG SECTOR

D6h

ENABLE SMART OPERATIONS

D8h

DISABLE SMART OPERATIONS

D9h

RETURN SMART STATUS

DAh

Table 16: SMART commands

3.5 Host Protected Area Command Set

The ASD26-HA2 series 2.5" SATA 3 Gb/s SSD supports the Host Protected Area command set which consists

of

.READ NATIVE MAX ADDRESS

.SET MAX ADDRESS

.READ NATIVE MAX ADDRESS EXT

.SET MAX ADDRESS EXT

The ASD26-HA2 series 2.5" SATA 3 Gb/s SSD supports the following optional commands.

.SET MAX SET PASSWORD

.SET MAX LOCK

.SET MAX FREEZE LOCK

.SET MAX UNLOCK