5 host protected area command set, 6 48-bit address command set – ADLINK ASD26-MT1 ET Series User Manual
Page 24

24
Specification
Table 16: SMART commands
3.5 Host Protected Area Command Set
The ASD26 series 2.5" SATA SSD supports the Host Protected Area command set which consists of
.READ NATIVE MAX ADDRESS
.SET MAX ADDRESS
.READ NATIVE MAX ADDRESS EXT
.SET MAX ADDRESS EXT
The ASD26 series 2.5" SATA SSD supports the following optional commands.
.SET MAX SET PASSWORD
.SET MAX LOCK
.SET MAX FREEZE LOCK
.SET MAX UNLOCK
3.6 48-Bit Address Command Set
The ASD26 series 2.5" SATA SSD supports the Host Protected Area command set, which consists of
Subcommand
Code
LBA Low value
SMART ATTRIBUTE VALUES (READ DATA)
D0h
READ ATTRIBUTE THRESHOLDS
D1h
ENABLE/DISABLE ATTRIBUTE AUTOSAVE
D2h
SAVE ATTRIBUTE VALUES
D3h
EXECUTE OFF-LINE IMMEDIATE
D4h
EXECUTE SMART OFF-LINE ROUTINE
00h
EXECUTE SMART SHORT SELF-TEST ROUTINE (OFFLINE)
01h
EXECUTE SMART EXTENDED SELF-TEST ROUTINE (OFFLINE)
02h
ABORT OFF-LINE ROUTINE
7Fh
EXECUTE SMART SHORT SELF-TEST ROUTINE (CAPTIVE)
81h
EXECUTE SMART EXTENDED SELF-TEST ROUTINE (CAPTIVE)
82h
READ LOG SECTOR
D5h
WRITE LOG SECTOR
D6h
ENABLE SMART OPERATIONS
D8h
DISABLE SMART OPERATIONS
D9h
RETURN SMART STATUS
DAh