beautypg.com

ADLINK ASD26-MT1 ET Series User Manual

Page 11

background image

Specification

11

1.2.14. Electromagnetic Immunity:

Electromagnetic Immunity tests assume the SSD is properly installed in the representative host system. The
drive operates properly without errors degradation in performance when subjected to radio frequency (RF)
environments defined in the following table.

Test

Description

Performance criteria Reference standard

Electrostatic discharge

Contact, HCP, VCP: ±8KV

Air: ±15KV

B

EN 61000-4-2:95

Radiated RF immunity

80~1000MHz, 3V/m,

80% AM with 1 KHz sine

900 MHz, 3 V/m, 50%

pulse modulation at

200Hz

A

EN 61000-4-3:96

ENV 50204:95

Electrical fast transient

±1KV on AC mains

±0.5KV on external I/O

B

EN 61000-4-4:95

Surge immunity

±1KV differential ±2KV

common, AC mains

B

EN 61000-4-5:95

Conducted RF immunity

150KHz~80 MHz, 3 Vrms,

80% AM with 1KHz sine

A

EN 61000-4-6:97

Voltage dips, interrupts

0% open, 5 sec
0% short, 5 sec

40%, 0.10 sec
70%, 0.01 sec

C
C
C
B

EN 61000-4-11:94

Table 12: Radio Frequency Specifications

Notes:

1.

Performance criterion A = The device shall continue to operate as intended, i.e.,
normal unit operation with no degradation of performance.

2.

Performance criterion B = The device shall continue to operate as intended after
completion of test, however, during the test, some degradation of performance is
allowed as long as there is no data loss operator intervention to restore device
function.

3.

Performance criterion C = Temporary loss of function is allowed. Operator
intervention is acceptable to restore device function.

4.

Contact electrostatic discharge is applied to drive enclosure.


1.2.15. Weight: 80 g (with enclosure)

1.2.16. Dimension: 100.0mm x 69.8mm x 9.5 mm (L x W x H)

This manual is related to the following products: