Command Set

79

(Status)

0 : Data has been sent at least once before.
1 : Data has been sent for the first time since a

synchronized sampling command was
issued.(1-character)

(IOFlag)

Status of programmable I/O
0x00: A(O/P) B(O/P) CH(O/P) CL(O/P)
0x01: A(O/P) B(O/P) CH(O/P) CL(I/P)
0x02: A(O/P) B(O/P) CH(I/P) CL(O/P)
0x03: A(O/P) B(O/P) CH(I/P) CL(I/P)
0x04: A(O/P) B(I/P) CH(O/P) CL(O/P)
0x05: A(O/P) B(I/P) CH(O/P) CL(I/P)
0x06: A(O/P) B(I/P) CH(I/P) CL(O/P)
0x07: A(O/P) B(I/P) CH(I/P) CL(I/P)
0x08: A(I/P) B(O/P) CH(O/P) CL(O/P)
0x09: A(I/P) B(O/P) CH(O/P) CL(I/P)
0x0A: A(I/P) B(O/P) CH(I/P) CL(O/P)
0x0B: A(I/P) B(O/P) CH(I/P) CL(I/P)
0x0C: A(I/P) B(I/P) CH(O/P) CL(O/P)
0x0D: A(I/P) B(I/P) CH(O/P) CL(I/P)
0x0E: A(I/P) B(I/P) CH(I/P) CL(O/P)
0x0F: A(I/P) B(I/P) CH(I/P) CL(I/P)
*I/P input mode, O/P output mode.

(DataOut)

Value of digital output channel. (2-character)

(DataIn)

Value of digital input channel. (2-character)

(DIn)

Value of dedicated digital input channel 3-0 for
ND-6058. The first character is 0 (2-character)

(DataInH)

Value of digital input channel 15-8 (2-character)

(DataInL)

Value of digital input channel 7-0 (2-character)

(DataInA)

Value of port A channel 7-0 (2-character)

(DataInB)

Value of port B channel 7-0 (2-character)

(DataInC)

Value of port C channel 7-0 (2-character)