4 troubleshooting and preventative maintenance, 1 troubleshooting the pxis-2670, Troubleshooting the pxis-2670 – ADLINK PXIS-2670 User Manual
Page 23: 4troubleshooting and preventative maintenance
Troubleshooting and Preventative Maintenance
15
4
Troubleshooting and Preventative
Maintenance
4.1 Troubleshooting the PXIS-2670
Please refer to Table 4-1 to troubleshoot the PXIS-2670 chassis.
The table lists possible causes for power failure and recommends
ways to correct the problem.
Possible Cause
What to Do
PXIS-2670 is not connected to
power source.
Make sure that the PXIS-2670 is connected to a live
electrical outlet. Try operating another piece of equip-
ment from this outlet.
Power switch is not switched on. Make sure the power switch is set to the ON position.
Power supply has failed.
Contact ADLINK for repair.
The Alarm Buzzer is beeping
Push Alarm RST button to stop beeping and refer to
Chapter 2.3 to find out which alarm occurs.
X
Temperature LED flashes:
X
Cool down the PXIS-2670 system
under 50
°
C.
X
Fan LED flashes:
X
Refer to Chapter 4.4 for the fan hot-
swap replacement.
Table 4-1: Troubleshooting