beautypg.com

6 parallel port – Acrosser AR-B1550 User Manual

Page 13

background image

AR-B1550 User

s Guide

11

Desired Baud Rate

Divisor Used to Generate 16x Clock

300

384

600

192

1200

96

1800

64

2400

48

3600

32

4800

24

9600

12

14400

8

19200

6

28800

4

38400

3

57600

2

115200

1

Serial Port Divisor Latch

2.6 PARALLEL PORT

(1) Register Address

Port Address

Read/Write

Register

base + 0

Write

Output data

base + 0

Read

Input data

base + 1

Read

Printer status buffer

base + 2

Write

Printer control latch

Registers’ Address

(2) Printer Interface Logic

The parallel port of the W83977F-A is for attaching various devices that accept eight bits of parallel data at
standard TTL level.

(3) Data Swapper

The system microprocessor can read the contents of the printer’s Data Latch through the Data Swapper by reading
the Data Swapper address.

(4) Printer Status Buffer

The system microprocessor can read the printer status by reading the address of the Printer Status Buffer. The bit
definitions are described as follows:

X

X

X

1

2

3

4

5

6

7

0

-ERROR
SLCT
PE
-ACK
-BUSY

Printer Status Buffer

NOTE: X presents not used.