beautypg.com

Ar-b5800 user manual, Rtc1 31. ccmos1, Jp4 (for lan3/lan4 bypass function select.) – Acrosser AR-R5800 User Manual

Page 16

background image

AR-B5800 User Manual

28. SYS_FAN1 (System FAN connector 1).

29. JP1 (For LAN1/LAN2 Bypass Function
Select.).

PIN

SIGNAL

1

GND

2

+12V

3

Fan speed data

Pins 1 and 2 shorted

(Default): Forced Normal.

Pins 2 and 3 shorted:

Controlled By CPLD.

Otherwise : Forced Bypass

30. RTC1

31. CCMOS1.

CMOS Backup Battery:

An onboard battery saves the CMOS memory to

keep the BIOS information stays on even after

disconnected your system with power source.

Nevertheless, this backup battery exhausts after

some five years.

Once the error message like “CMOS BATTERY

HAS FAILED” or “CMOS checksum error

displays on monitor, this backup battery is no

longer functional and has to be renewed

32. JP4 (For LAN3/LAN4 Bypass Function
Select.).

Pins 1 and 2 shorted

(Default): Forced Normal.

Pins 2 and 3 shorted:

Controlled By CPLD.

Otherwise : Forced Bypass

16