beautypg.com

Operating instructions, Unpacking and cleaning, Extension cords – Delta 31-552 User Manual

Page 5: Foreword

background image

5

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which
has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an
extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause
a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct gauge to use depending
on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

EXTENSION CORDS

OPERATING INSTRUCTIONS

FOREWORD

The Delta 6" Abrasive Belt Finishing Machine provides fine finishes fast. The 6" abrasive belt operates vertically,
horizontally or any angle in between. The support table on the 6" Abrasive Belt Finishing Machine tilts 45° out and 20°
in for bevel operations.

UNPACKING AND CLEANING

Carefully unpack the machine and all loose items from the shipping container(s). Remove the protective coating from
all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone,
gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household
floor paste wax.

Fig. D

Fig. D

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

115

up to 25

18 AWG

0-6

115

25-50

16 AWG

0-6

115

50-100

16 AWG

0-6

115

100-150

14 AWG

6-10

115

up to 25

18 AWG

6-10

115

25-50

16 AWG

6-10

115

50-100

14 AWG

6-10

115

100-150

12 AWG

10-12

115

up to 25

16 AWG

10-12

115

25-50

16 AWG

10-12

115

50-100

14 AWG

10-12

115

100-150

12 AWG

12-16

115

up to 25

14 AWG

12-16

115

25-50

12 AWG

12-16

115

GREATER THAN 50 FEET NOT RECOMMENDED

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

230

up to 50

18 AWG

0-6

230

50-100

16 AWG

0-6

230

100-200

16 AWG

0-6

230

200-300

14 AWG

6-10

230

up to 50

18 AWG

6-10

230

50-100

16 AWG

6-10

230

100-200

14 AWG

6-10

230

200-300

12 AWG

10-12

230

up to 50

16 AWG

10-12

230

50-100

16 AWG

10-12

230

100-200

14 AWG

10-12

230

200-300

12 AWG

12-16

230

up to 50

14 AWG

12-16

230

50-100

12 AWG

12-16

230

GREATER THAN 100 FEET NOT RECOMMENDED