110361-01G

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

CAUTION: Never connect

propane/LP heater directly to the

propane/LP supply. This heater

requires an external regulator

(not supplied). Install the exter-

nal regulator between the heater

and propane/LP supply.

WARNING: Never connect

natural gas heater to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

Installation Items Needed

Before installing heater, make sure you have the

items listed below.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

* An CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 26.

For propane/LP units, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11" and 14" of

water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down as

shown in Figure 6. Pointing the vent down protects

it from freezing rain or sleet.

INSTALLATION

Continued

Figure 5 - Gas Regulator Location and

Gas Line Access Into Stove Cabinet

Front of
Stove
Unit

Gas Regulator
Inlet Connection

Back View

Side View

6"

Minimum

48"

Minimum

Ceiling

Floor

Back Wall

Figure 6 - External Regulator With Vent

Pointing Down

CAUTION: Use only new, black

iron or steel pipe. Internally-tinned

copper tubing may be used in

certain areas. Check your local

codes. Use pipe of 1/2" diameter

or greater to allow proper gas

volume to heater. If pipe is too

small, undue loss of volume

will occur.

Installation must include an equipment shutoff valve,

union and plugged 1/8" NPT tap. Locate NPT tap

within reach for test gauge hook up. NPT tap must be

upstream from heater (see Figure 7, page 10).
IMPORTANT:

Install equipment shutoff valve

in an accessible location. The equipment shutoff

valve is for turning on or shutting off the gas to

the appliance.

Check building codes for any special require-

ments for locating equipment shutoff valve to

fireplaces.

Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

External
Regulator

Propane/LP
Supply Tank

Vent
Pointing
Down

This manual is related to the following products: