OPERATION (cont.)

DRAIN PUMP KIT (Optional)
(Classic Plus 26 model ONLY)

A drain pump kit (CPK-4) is available to allow continuous operation and
to eliminate the need for a drain tank.

When the water collects to level
(A) in the pump reservoir, the
drain pump begins to operate
and discharge the water.

DISCHARGE HOSE

DRAIN PUMP

DRAIN PUMP
RESERVOIR

A

B

When the water level drops below level (B), the drain pump stops,
and the compressor will restart.

NOTE: If for any reason the water level exceeds that of level (A) in
the pump reservoir, an overflow Drain Switch will stop the com-
pressor operation.

NOTE: If the Fan Mode Control DIP Switch (see pg. 11) is set to the
STOP position, the entire unit (including fan operation) will turn off
due to the overflow Drain Switch.