Digicom GSM 2G WLL User Manual
Page 2
For further information
visit our website
http://www.digicom.it
2G WLL has an internal backup battery that guarantees
its operation even when power is off.
If you need to connect your phone controller to your
alarm control unit, you can connect it to 2G WLL and,
wihout any additional configuration, the phone calls will
be made through the GSM network.
Internet and E-mail always available. Digicom 2G WLL
is also a GPRS/GSM USB modem to be always online.
TECHNICAL FEATURES
GSM/GPRS
l
GSM network type Quad-band 850/900/1800/1900 MHz
l
GSM Module: GSM/GPRS TM2
l
Transmitter power: Class 4 (2W) for EGSM at 850/900MHz and
Class 1 (1W) for DCS at 1800/1900MHz
l
GPRS Class 10
l
SIM card: 3V compatible (Plug in, small)
Phone and Fax Interface
l
Voice Interface: FXS
l
2 Connectors: RJ11 6/2 (voice and fax)
l
Off-hook AC impedance: 600 ohm
l
On-hook line voltage: 48VDC
l
Off-hook line current: 25mA
l
Dialing type: Tone (DTMF), Pulse (optional)
l
Ringing voltage: 48 VAC rms - REN: 3
l
Metering pulses generation: 16 KHz (optional)
l
Polarity reversal (optional)
Connection
l
Voice call
l
Analog Group 3 fax
l
GPRS up to 85Kbps
l
Short Messaging Service (SMS)
l
CSD up to 9.6 Kbps
Power supply
l
External adapter
l
Input: 100-240 VAC / 50-60Hz / 0,5A
l
Output: 9VDC / 1.0A
Battery Backup
l
Standby time: 8h
l
Talk time: 2h
GSM Antenna
l
Quad-Band Omnidirectional Antenna (included)
l
Connector type: SMA
l
Impedance: 50 ohm
l
High gain omnidirectional external antenna (optional)
l
High gain directional external antenna (optional)
Data Interface
l
Data interface: USB 1.1 (2.0 compatible)
l
Connector type: USB mini B
l
Driver: Windows Vista, XP, 2000
Other
l
Dimensions: 180x137x40mm
l
Operating Temperature: -0°/55°
l
Walll mount kit (optional)
l
Leds: Power/Error, Status, Mode, Memory, Battery
l
CE Mark and Rohs compliant
GSM/GPRS
Security Service
Sensors
2G WLL
Alarm
Control Unit