beautypg.com

DeVilbiss JGA-510 User Manual

Page 7

background image

SB-2-252-J Page 7

TROUBLESHOOTING (continued)

CONDITION

CAUSE

CORRECTION

Fluid leaking or dripping

Packing nut too tight.

Adjust

from front of pressure
feed gun

Dry packing.

Lubricate.

Fluid tip or needle worn or damaged.

Replace tip and needle with lapped sets.

Foreign matter in tip.

Clean.

Fluid needle spring broken.

Replace.

Wrong size needle or tip.

Replace.

Runs and sags

Too much material flow.

Adjust gun or reduce fluid pressure.

Material too thin.

Mix properly or apply light coats.

Gun tilted on an angle, or gun motion

Hold gun at right angle to work and adapt to

too slow.

proper gun technique.

Thin, sandy coarse finish

Gun too far from surface.

Check distance. Normally approximately 8".

drying before it flows out

Too much air pressure.

Reduce air pressure and check spray pattern.

Improper thinner being used.

Follow paint manufacturer's mixing instructions.

Thick, dimpled finish

Gun too close to surface.

Check distance. Normally approximately 8".

"orange peel".

Too much material coarsely atomized.

Increase air pressure or reduce fluid pressure.

Air pressure too low.

Increase air pressure or reduce fluid pressure.

Improper thinner being used.

Follow paint manufacturer's mixing instructions.

Material not properly mixed.

Follow paint manufacturer's mixing instructions.

Surface rough, oily, dirty.

Properly clean and prepare surface.