Problem: feedwater fault light on, Problem: ice delivery volume seems inadequate, Problem: water leaks – Dometic Eskimo Ice Remote Ice Crushing System User Manual

Page 13: Problem: oil in auger assembly drain pan

background image

13

Y

Y

Y

Y

Y

English

L-2448B Operation

Problem: Feedwater fault light on

Potential solution:

1) Check for water pressure in boat’s potable water

system

2) Check for a valve that has been turned off

3) Check for a clogged feedwater filter.

4) Check for a clogged needle valve in the water

reservoir.

Problem: Ice delivery volume seems
inadequate

Potential Cause/Solution:

1) High seawater temperature

2) High feedwater temperature

3) Low seawater flow, check pump and strainer

4) Drivemotor weak, replace motor

5) Corroded or stained auger due to water

condition, clean and/or replace assembly

6) Inlet water filter/strainer partially clogged,

replace filter

7) Loss of refrigerant charge, consult trained

technician

Problem: Water Leaks

Potential Cause/Solution:

1) Defective Water seal, replace seals

2) Water level in reservoir too high, adjust float

Problem: Excessive noise or chattering
from evaporator/auger assembly

Potential Cause/Solution:

1) Mineral or scale deposit on auger and evaporator

walls. Clean evaporator

2) Poor water supply, check for fouled filter or float

valve

3) Gear reducer assembly loose on mounts

4) Gearmotor end-play of worn bearing, replace

worn part

Problem: Oil in auger assembly drain pan

Potential Cause/Solution

1) Water in gear reducer has raised level of the oil

so that it can run out of the weep hole on the
top of the gear housing. It may occur due to:

i. Leaking water seals in the evaporator/auger
assembly, replace seals.

ii. Loose or missing drain hose on weep hole,
which might allow condensate to leak into the
weep hole.