Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns
and electrical shock can occur.

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

1. No electrical power to heater

2. Fan hitting inside of heater shell

3. Fan blades bent

4. Defective motor

1. User did not follow installation or

operation instructions properly

2. No spark at ignitor. To test for spark,

follow step 8 under Ignitor, page 9.
If you see spark at ignitor, have
heater serviced by qualified service
person. If no spark seen:

A) Loose or disconnected ignitor

wire

B) Wrong spark gap

C) Piezo ignitor loose

D) Bad ignitor electrode

Fan does not turn when heater is
plugged in

Heater will not ignite

1. Check voltage to electrical outlet. If

voltage is good, check heater power
cord for breaks

2. Adjust motor/fan guard to keep fan

from hitting inside of heater shell.
Bend fan guard if necessary

3. Replace fan. See Fan, page 8

4. Replace motor. See Motor, page 8

1. Repeat installation and operation

instructions. See Installation, page 6
and Operation, page 6

2.

A) Check ignitor wire. Tighten or

reattach loose ignitor wire. See Figure
14, page 9 for ignitor wire location

B) Set gap between ignitor electrode
and target plate to .17"

C) Tighten nut holding piezo ignitor
to base of heater

D) Replace ignitor electrode. See
Ignitor, page 9