beautypg.com

Operating heater – Desa GWRP10 User Manual

Page 13

background image

www.desatech.com

13

107902-01K

Thermocouple

Pilot Burner

Figure 18 - Pilot

Ignitor Electrode

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information, page 12.

2. Make sure equipment shutoff valve is fully

open.

3. Turn off any electric power to the appliance

if service is to be performed.

4. Turn control knob clockwise

to the

OFF position.

5. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information, page 12. If you don’t smell gas,

go to the next step.

6. Press in and turn control knob counterclock-

wise

to the PILOT position. Keep

control knob pressed in for five (5) seconds.

7. With control knob pressed in, push down and re-

lease ignitor button. This will light pilot. The pilot

is attached to the front of burner. Note: You may be

running this heater for the first time after hooking

up to gas supply. If so, you may need to press in

control knob for 30 seconds or more. This will

allow air to bleed from the gas system. If needed,

keep pressing ignitor button until pilot lights. If

ignitor does not light pilot, refer to Troubleshoot-

ing, page 16 or contact a qualified service person

or gas supplier for repairs. Until repairs are made,

light pilot with match. To light pilot with match,

see Manual Lighting Procedure, page 14.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop up when re-

leased, contact a qualified service person or

gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 thru 7.

9. Turn control knob counterclockwise

to

desired heating level. The main burner should

light. Manual control heaters should be used

in locked positions.

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

Figure 17 - Control Knob In The OFF

Position

OPERATING HEATER

Continued

TO SELECT

HEATING LEvEL

WARNING: When running

heater, set control knob at LOW

or HIGH locked positions. Never

set control knob between locked

positions. Poor combustion and

higher levels of carbon monox-

ide may result.

Slightly press in control knob and turn counter-

clockwise

to the LOW or HI positions.

IMPORTANT:

Release downward pressure while

turning control knob. Control knob will lock at the

desired position.

Ignitor Button

Control
Knob

LOW

OFF

PILOT

HIGH

OFF

PILOT

OFF

Control Knobs Burners

Figure 19 - Burner Patterns

CAUTION: Do not try to ad-

just heating levels by using the