Electrical connection, Building in – AEG 33620 DK-M User Manual
Page 8
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Installation
The appliance must be electrically disconnected before all interventions. If any electric
supply to the appliance is required to carry out the work, ensure all the necessary precau
tions are followed.
The side walls of the unit in which the hob is going to be installed, must not exceed the
height of the working top.
Avoid installing the appliance in the proximity of inflammable materials (e.g. curtains, tea
towels etc.).
Electrical Connection
The appliance is designed to be connected to 230 V monophase electricity supply.
The connection must be carried out in compliance with the laws and regulations in force.
Before the appliance is connected:
1. check that the main fuse and the domestic installation can support the load (see the
rating label).
2. check that the power supply is properly earthed in compliance with the current rules.
3. check the socket or the double pole switch used for the electrical connection can be
easily reached with the appliance built in the furniture unit.
The appliance is supplied with a connection cable. This has to be provided with a proper
plug, able to support the load marked on the identification plate.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system, it is necessary that you install a
double pole switch between the appliance and the electricity supply, with a minimum gap
of 3 mm. between the switch contacts and of a type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in order that, in each part, it cannot reach a tem
perature 90 °C higher than the room temperature.
The brown coloured phase cable (fitted in the terminal block contact marked with "L") must
always be connected to the network phase.
Replacement of the connection cable:
The replacement of the connection cable requires the specific equipment of a technician.
In this case, only cable type H05V2V2-F T90 must be used. The cable section must be suitable
to the voltage and the working temperature.
The yellow/green earth wire must be approximately 2 cm longer than the phase wires .
Building In
These hobs can be inserted in a built-in kitchen unit whose depth is between 550 and 600
mm.
Installation and assembly
8