PRESSURE LIMIT CONTROL
(St
0
am Boilers Only)
'This control will shnt off the gas supply to the bur
ners in the event that the steam pressure in the
boiler reaches the *'cut-out” setting. It will also
permit gas flow to the burners when the steam pres
sure drops to the “cuHn"* setting. The range be
tween these two settings is called the *'differen
tial”. The cut-out pressure is equal to the cut-in
pressure setting plus the differential.
LOW WATER CUT-OFF
(Steam Boilers Only)
This control operates to shut off the gas supply to
the burner in the event that the water line in the
boiler drops to a low level. It also permits ga^ flow *
to the burners when sufficient water is ^dded to the
boiler, either by opening a water valve manually or
be an electric water feeder.
f t l b U C T I I N P I P E S I Z E
^ N O T T O B E M A D E B E F O R E H E R E .
£ " P I P E
Racomm ended
steam Heoder
proportions for
70, 105, 140.
Under no circum-
otoncofi should the
risers he reduced
in six* before the
first horizontal
run.
' 'Re'coinmefi'dSd''
8t*am heoder
proportions for
175
,
210
.
Under no circtitn-
stances should tl
risers be reducec
in size before th<
first
horizontal
run.