for purchasing a Maytag water heater.
Properly installed and maintained, it should give you years of
trouble free service. It is strongly suggested that this new
water heater be professionally installed., call Maytag Customer
Service at 1-800-788-8899 for recommended installers.
Abbreviations Found In This Instruction Manual
U.L.- Underwriters Laboratories, 333 Pfingsten Rd.,
Northbrook, IL 60062
National Electrical Code-This publication is available from
your local government or public library or electric company or
by writing to U.L. above.
ANSI-American National Standards Institute
• Read the “Safety Instructions” section, pages
2
and 3 of this
manual first and then the entire manual carefully. If you
don’t follow the safety rules, the water heater wiU not oper
ate properly. It could cause DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, oper
ation, and maintenance of this electric water heater. It also
contains warnings throughout the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THIS ENTIRE MANUAL BEFORE
ATTEMPTING TO INSTALL OR OPERATE THE
WATER HEATER.
Customer Information
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition of the
National Electrical Code. This publication is available from
your local government or public library or electric company
or by writing Underwriters Laboratories, 333 Pfingsten
Road, Northbrook, IL 60062.
If after reading this manual you have any questions or do
not understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
Carefully plan the place where you are going to put the
water heater. Correct electrical wiring and connections are
very important in preventing death from possible electrical
shock and fires.
Examine the location to ensure the water heater complies
with the “Locating the New Water Heater” section.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce
dures. Instructions may be obtained from the California
office of the State Architect, 400 P Street, Sacramento, CA
95814.
Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00.
Product Specifications
Model
HE21250PC
HE21282PC
Tank Capacity
In Gallons
50
80
Element Upp„
3800
3800
at 240 Volt Lower
3800 1 5500
3800 1 5500
Recovery Rate Upper
17.3
17.3
@ 90°F Rise Lower
17.3 1 25
17.3
25
Diameter
22
"
26.25"
Height
58.5"
62"
Maximum Fuse or
Circuit Breaker Size
20
30
20
30
Minimum
Wire Size (Gauge)*
12
10
12
10
*Wiring size based on standard 60°C copper wire. If distance from
fuse box to water heater is more than 90 feet, refer to your local
electrical code.