RS-232C Communication (continued)
Communicaion settings
1. Protocol
19200bps,8N1
2. Command format
("h" shows hexadecimal)
Byte Number
0
1
2
3
4
5
6
7
8
9 10 11 12
Command
Action
Header
Data
Header
code
Packet
Data
size
CRC
flag
Action
Type
Setting
code
L
H
L
H
L
H
L
H
L
H
L
H
desired value [(cL)(cH)]
by [(eL)(eH)].
BEh EFh
03h 06h 00h
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
internal setup value [(bL)
(bH)] .
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
Increment setup value
[(bL)(bH)] by 1.
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
Decrement setup value
[(bL)(bH)] by 1.
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
command [(bL)(bH)].
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
[Header code] [Packet] [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4.
[CRC flag]
For byte number
5, 6,
refer to
RS-232C Communication / Network command
table
(
&
17
)
.
[Action]
Set functional code to byte number 7, 8.
Refer to the Communication command table
(
&
above
).
[Type] [Setting code]
For byte number
9 ~ 12
, refer to
RS-232C Communication / Network command
table
(
&
17
)
.