beautypg.com

PJLink CP-A220N User Manual

Page 32

background image

32

PJLink command (continued)

Commands

Control Description

Parameter or Response

ERST ?

Error Status inquiry

1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Lamp error; one of 0 to 2
3rd byte: Refers to Temptrature error; one of 0 to

2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2

The mearning of 0 to 2 is as given below
0 = Error is not detected; 1 = Warning; 2 =

Error

LAMP ?

Lamp Status inquiry

1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on

INST ?

Input Source List inquiry 11 12 22 23 31 41 51 52

NAME ?

Projector Name inquiry

Responds with the name set in "PROJECTOR

NAME" of "NETWORK"

INF1 ?

Manufucturer's Name

inquiry

HITACHI

INF2 ?

Model Name inquiry

CP-A220N
CP-A300N

INFO ?

Other Information inquiry Responds with the factory information and so

on

CLSS ?

Class Information inquiry 1

NOTE • The password used in PJLink

TM

is the same as the password set in

the Web Brouwser Comtrol. To use PJLink

TM

without authentication, do not set

any password in Web Browser Control.

• For specifications of PJLink

TM

, see the web site of the Japan Business

Machine and Information System Industries Association.

URL: http://pjlink.jbmia.or.jp/

This manual is related to the following products: