Before calling for service – Amana Quiet Zone 7M11TA User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

1ETH0DTW0:
. Remove the front grille.
Slide the grille to the left until it clears the unit clips and
pull out.
. Grasp the filter handle and slide the filter to the left until
it clears the unit clips and pull out.
Reinstall air filter by reversing above procedure.
NOTE: A charcoal air purification filter accessory is avail
able that reduces smoke, odor, pollen, and fine dust par
ticles. See your store dealer for details or call Amana at 1
800-843-0304.
IMPORTANT NOTE: A dirty air filter reduces operating
efficiency. Inspect filter at least once every week during
operation. Clean filter with a vacuum cleaner or warm,
soapy water. Thoroughly dry filter before replacing. Do not
operate unit without filter.
Fan Motor
Fan motor is permanently lubricated so there is no need to
oil motor.
Slide out Chassis
Some models feature a slide out chassis for easier instal
lation, Refer to Installation Instructions provided with unit
for details on removing chassis from outer case.
Before Calling For Service
Difficulty
Possible Cause
Suggested Solution
Air conditioner will not operate.
No power to unit.
Set fan control to position other than off.
Confirm power cord is plugged in.
Check fuse or circuit breaker.
Little or no cooling.
Compressor lockout on initial plug-in.
Wait 3 to 4 minutes and recheck compressor.
Dirty air filter.
Clean air filter.
Air conditioner undersized for
application.
Check with dealer to determine proper unit
capacity for application.
Power interruption or changing unit
settings.
Let fan run. Compressor will automatically
restart In approximately 3 to 4 minutes.
Noisy unit.
Loose parts.
Tighten any loose parts.
Weak building construction.
Provide additional support.
Water hitting fan blade.
Normal in high humidity.
Mounting support cannot be
installed.
Storm window frame has been
installed into window.
Some models require the window sill to be
adapted to accept the mounting support.
Refer to Installation Instructions provided with
the unit for details.
Odors in cooling.
Mold, mildew or algae formation on
wet surfaces.
Place algaecide tablet in base pan.
Water in base pan.
Water in base pan is picked up by
the fan blade and thrown onto the
warm outdoor coll where the water
then evaporates.
Normal in high humidity