Electrical Requirements
Electrical Grounding Instructions
This appliance isequipped with a three-prong grounding plug
for protection against possible shock hazards, if a two-prong
wall receptacle is encountered, the customer is required to
contact a qualified electrician and have the two-prong wall
receptacle replaced with a properly grounded three-prong
wall receptacle in accordance with the National Electrical
Code.
Room air cond itioners are designed to operate according to
requirements on the nameplate and as shown in Table 1,
Fuse or circuit breaker ratings must be accord ing to the fuse
instruction label and as shown in Table 1, Do not plug
models marked “Use on Single Outlet Circuit Only” into a
circuit with another appliance or light fixture.
WARNING
To avoid death, persona! injury or property
damage due to electrical shock, this unit
must be grounded. Do not under any
circumstances cut or remove the round
grounding prong from the plug. Do not use
a two-prong adapter.
A
WARNING
To avoid death, personal injury or property
damage due to electrical shock, do not use
an extension cord. Do not pinch the power
cord. Do not remove the warning tag from
the power cord.
Unit Plug Type
Receptacle
Circuit Rating,
Voltage Rating
Required
Breaker or
Time
Delay Fuse
On Unit Nameplate
víüy
125 V-15 AMP
115V
NEMA No. 5*15P
NEMA Nü, 5-15R
©
/"□A
J
250V-15 AM P
230/20SV rated
at 12 amperes or less
NEMA No. 6-15P
NEMA No. 6-15R
Z30/208V rated over
250V-20AMP
12 amperes but not more
NEMA No. 6-20P
NEMA No. 6-20R
than 16 amperes
©
\a ay
250V-30AMP
230/208V rated
at 24 amperes or less
NEMA No. 6-30P
NEMA No. 6-30R
Safety Features
This room air conditioner is equipped with an electronic
control to improve comfort and ensure reliability.
Compressor Lockout
To extend the life of the compressor a three minute time
delay will occur when:
•
Electrical power is first supplied to the unit
•
The thermostat is turned down immediately after the
compressor stops running.
•
The Fan Control is quickly turned from FAN ONLY to
COOLING mode or vice versa.
Low Voltage Protection
This unit is equipped with “brownout” protection. In case
of an extreme brownout, the Amana control will interrupt
power to the unit to prevent compressor failure. When the
line voltage reaches at least 100 VAC, the control will re
energize your unit.
Note: A compressor lockout will occur after the unit is re
energized.
Table 1
Advantages of Amana’s Electronic Controls
•Digital Temperature Setting
- Temperature can be set from 60°F to 90°F in 1°F
increments
•Digital Temperature Display
- Shows indoor room temperature in FAN ONLY
mode
- Shows desired temperature setting in other modes
Computer Memory that Remembers
- The unit remembers the last settings used when
last turned on.
•TempAsure'^ Thermostat
- Maintains set temperature within 1.5°F for maxi
mum comfort
•Smart Cool
•Energy Saver with TempAsure^ air sampling
•Delay Timer