Table for the choice of the injectors

I

NCREASE OF AIR NECESSARY FOR GAS COMBUSTION

(2 m

3

/h x kW)

BURNERS

Air necessary for combustion [m

3

/h]

Auxiliary (A)

2,00

Semi-rapid (SR)

3,50

Rapid (R)

6,00

Triple-ring (TR)

7,00

Oven

12,40

Grill

9,30

GB

Cat:

II

2H3+

*

= Reference value

BURNERS

Nominal

Power

[kW]

Reduced

Power

[kW]

G 30 - 28-30 mbar

G 31 - 37 mbar

G 20

20 mbar

Ø

injector

[1/100 mm]

Ring

opening

[mm]

Ø

injector

[1/100 mm]

Ring

opening

[mm]

Auxiliary (A)

1,00

0,30

50

-

72 (X)

-

Semi-rapid (SR)

1,75

0,45

65

-

97 (Z)

-

Rapid (R)

3,00

0,75

85

-

115 (Y)

-

Triple ring (TR)

3,50

1,50

95

-

135 (T)

-

Oven

6,20

1,30

120

8 *

180

1,5 *

Grill

4,65

-

107

Fully open

*

165

3 *