USING THE BUILT-IN BATTERY TESTER

OVERVIEW

This battery charger has a built-in battery
tester that displays either an accurate

battery voltage or an estimate of the
battery’s relative charge based on the
battery voltage and the Battery Council

International scale.

TESTING SEQUENCE
There are four basic steps required to

use the 71225 as a battery tester.

1. Connect the charger battery clamps to

the battery. Be sure to follow all of the

precautions listed under “OPERATING

INSTRUCTIONS”.

2. Connectthe charger power cord to a 120V

AC 2-prong wall outlet. Again, be sure to
follow all of the precautions listed under

“OPERATING INSTRUCTIONS”.

3. If necessary, press the BATTERY

TYPE button until the correct type Is

indicated.

4. Read the voltage on the digital display

or press the display mode button to set

the tester to BATTERY % and read the

battery percent.

TESTER AND CHARGER

When first turned on, the 71225 oper­

ates only as a tester, not as a charger. To
continue to use it as only a tester, avoid
pressing the CHARGE RATE switch but­

ton. Selecting a charge rate activates the

battery charger and deactivates the tester.

Pressing the CHARGE RATE button when

the 80A Start LED is lit (except during the

180 second cool down) will shut off the

charger and activate the tester.

POWER-UP IDLE TIME LIMIT

If no switch button Is pressed within 15
minutes after the battery is first powered
up, the charger will automatically switch

from tester to charger, if a battery is

connected. In that case, the battery will
be set for the 2A charge rate and 12V

REGULAR battery type.

TESTER WITHOUT

TIME

LIMIT

If either the DISPLAY MODE or BAT­

TERY TYPE button Is pressed within
the first ten minutes after the battery is

powered up, the battery will remain a

tester (not a charger) indefinitely, unless
a charge rate is selected.

TESTING

AFTER CHARGING

After the battery has been changed from

tester to charger (by selecting a charge

rate), it remains a charger. To change

the battery back to a tester, press the

CHARGE RATE switch until all charge
rate LEDs are off.

TESTER STATUS LEDs

When the 71225 is operating as a bat­
tery tester, the status LEDs light under
the following conditions:

• The CHARGED (green) LED will light if

a charged battery is tested.

• The CHARGING (yellow) LED does not

light in the battery test mode.

• The CHECK (red) LED lights unless a

properly connected battery is detected.

• When the tester display mode is set to

VOLTAGE, the CHARGEDand CHARG­

ING LEDs won't light.

INITIAL PERCENT CALCULATION

When a battery % is calculated for the
first time after connecting a battery, the
digital display will show three dashes

(“—”) for a period as long as several

seconds while the tester analyzes the

battery.

NOTES FOR TESTING BATTERY %

A recently charged battery could have a

temporarily high voltage due to what is

known as “surface charge”. The voltage

of such a battery will gradually drop during
the period immediately after the charging
system is disengaged. Consequently, the
tester could display inconsistent values

for such a battery. For a more accurate

reading, the surface charge should be
removed by temporarily creating a load on

the battery, such as by turning on lights or
other accessories.

The battery % ranges from 0 to 100.

The battery tester is only designed to test

batteries. Testing a device with a rapidly

changing voltage could yield unexpected
or inaccurate results.

11