DO NOT INSTALL YOUR DRYER:
1.
In
an
area
exposed
to
dripping
water
or
outside
weather
conditions.
In an area where it will conne in contact with curtains, drapes,
or
anything
that
will
obstruct
the
flow
of
combustion
and
ventilation air.
On carpet. Floor
MUST be
solid with a maximum slope of 1
inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,
MUST be
exhausted outdoors.
2.
No other fuel
burning appliance shall
be installed in the
same closet as the Gas dryer.
Your dryer needs the space around it for proper ventilation.
DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A
SOLID DOOR.
3.
4.
A
minimum
of
120
square
inches
(JlA.l
square
cm)
of
opening, equally divided at the top and bottom of the door,
is
required.
Air
openings
are
required
to
be
unobstructed
when a door is installed. A louvered door with equivalent
air openings for the full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
FRONT SIDES REAR TOP
Alcove
0 (0 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet
1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15(38.1 cm)
Closet
door
ventilation
required:
2
louvered
openings
each
60
square inches (387 square centimeters) — 3 inches (7.6 cm)
from bottom and top of door.
THIS DRYER MUST BE EXHAUSTED OUTDOORS.
5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
Rigid
Metal
Only
Rigid
Metal
Only
Rigid
Metal
Only
Correct
Correct
6
Correct