Installation Instructions
Electric Furnace
Low Voltage
Pilot Hole
Alternate
LineVoitage
Pilot Hole
Drain Connections
For Horizontal
Main 3/4 Fpt
Overflow 3/4 FPT
Main/Overflow Drains
3/4 FPT
14-3/s” (EF08)
17-7/3” (EF12)
2I-V2” (EF16)
25-Vs” (EF20)
45” (EF08-12)
54” (EF16-20)
CLEARANCES
Filter Door
16-3/g” {EF08)
19-7/g” {EF12)
23-V2” {EF16)
27-Vg” {EF20)
NO HEATERS
All Sides ....................... ............................... . 0”
From Supply Duct......... ..................... .......... . 0”
Recommended Service From Front .................20”
(Service for blower, filter if installed)
WITH HEATERS
All Sides .. ............................................................0”
From First Three
Feet of Supply Duct to Combustibles.......... .
1”
From Duct after Three Feet ................................ 0”
Recommended Service From Front .................20”
(Service for blower, filter, heaters if installed)
Fire Hazard
When heaters are installed maintain clear
ances from combustible materials as speci
fied on unit rating plate.
Failure to do so can result in fire, property
damage, personal injury or death.
General Information
EZnnnnr
Installation or repairs made by unqualified persons can
result in hazards to you and others. Installation MUST
conform with local building codes and with the
National Electrical Code NFPA70 current edition.
The information contained in this manual is intended
for use by a qualified service technician familiar with
safety procedures and equipped with the proper tools
and test instruments.
Failure to carefully read and follow all instructions in
this manual can result in equipment malfunction,
property damage, personal injury and/or death.
THESE INSTRUCTIONS ASSUME THAT A TYPICAL INSTAL
LATION WILL INCLUDE ELECTRIC HEAT AND A COIL. BA
SIC INSTRUCTIONS ARE PROVIDED BUT THE INSTALLER
WILL HAVE TO REFER TO INSTRUCTIONS FOR OTHER AC
CESSORIES FOR MORE COMPLETE INFORMATION.
The blower cabinet may be used as an electric furnace or for cool
ing or heat pump operation with or without electric heat. The cabi
net can be instailed in an upflow, downflow or horizontal position
(Figure 2), Horizontal installations require a horizontal kit for prop
er coil support and drain pan, Downflow installations require a
subbase kit which provides proper clearances and a support to
install a coil.These units are not shipped with air filters installed.
Filter must be field supplied, either washable or disposal type.
Washable filters are available as an accessory.
Location
Select the best position which suits the installation site conditions.
The location should provide adequate structural support, space in
the front of the unit for service access, clearance for return air and
supply duct connections, space for refrigerant piping connections
and condensate drain line connections, and clearance forfilter re
moval.
NOTE: Internal filter can be accessed from separate filter door. If
the filter can NOT be easily accessed, a remote filter is recom
mended. Refer to ACCA Manual D for remote filter sizing.
If the unit is located in an area of high humidity, nuisance sweating
of casing may occur. On these installations a wrap of 2” fiberglass
insulation with a vapor barrier should be used.
Upflow Installations
The unit is ready to install in the upflow position without modifica
tions.
The unit MUST be supported on the bottom ONLY and set on a
supporting frame or shelf. Use screws through the bottom to an
chor to supporting frame.
Downflow Installations
Refer to instructions with Subbase Kit.