Locating the New Water Heater
Facts to Consider About the
Location
You should carefully choose an indoor location for the
new water heater, because the placement is a very impor
tant consideration for the safety of the occupants in the
building and for the most economical use of the appli
ance.
This water heater is not for use in mobile homes or
outdoor installation.
Whether replacing an old water heater or putting the
water heater in a new location, the following critical
points must be observed.
1. The location selected should be indoors as close as
practical to the gas vent or chimney to which the
water heater vent is going to be connected, and as
centralized with the water piping system as possible.
The water heater, as all water heaters, will eventually
leak. Do not install without adequate drainage provi
sions where water flow will cause damage.
WARNING
Propellants of aerosol sprays and volatile compounds,
(cleaners, chlorine based chemicals, refrigerants, etc.) in
addition to being highly flammable in many cases, will
also change to corrosive hydrochloric acid when exposed
to the combustion products of the water heater. The
results can be hazardous, and also cause product failure.
2. The location selection must provide adequate clearances
for servicing and proper operation of the water heater.
--------------------WARNING-------------------
This water heater must not be installed directly on cari
Carpeting must be protected by a metal or wood panel beneatl
. 1
1
.
1
. .^ L j .
1
.
, 1 1
!j,i ^ depth of the
■■ ‘ or if
floor
must be covered by the panel. Failure to heed this warning may
result in a fire hazard.
CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of the
water heater must be accomplished in such a manner that if
the tank or any connections should leak, the flow of water
will not cause damage to the structure. When such loca
tions cannot be avoided, a suitable drain pan should be
installed under the water heater. Drain pans are available at
your local Sears store. Such a drain pan must be not greater
than 1 'A inches deep, have a minimum length and width of
at least 2 inches greater than the water heater dimensions
and must be piped to an adequate drain. The pan must not
restrict combustion air flow. Under no circumstances is the
manufacturer or Sears to be held liable for any water dam
age in connection with this water heater.
WARNING
INSTALLATIONS
IN
AREAS
WHERE
FLAMMABLE
LIQ
UIDS
(VAPORS)
ARE
LIKELY
TO
BE
PRESENT
OR
STORED
(GARAGES,
STORAGE
AND
UTILITY
AREAS,
ETC):
Flammable
liquids
(such
as
gasoline,
solvents,
propane (LP) or butane, etc.) or other substances (such
as adhesives, etc.), all of which emit flammable vapors,
may be improperly stored or used in such areas. The
gas water neater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious burns to anyone in the area, as well as
property damage.
if installation in such areas is your only option, then
the installation must be accomplished in a way that the
■ — ■ ■ ...
pilot flame and main burner flame are elevated from
the floor at least 18 inches. While this may reduce the
changes of flammable vapors from a floor spill being
ignited,
gasoline
and
other
flammable
substances
should never be stored or used in the same room or
area containing a gas water heater or other open flame
or spark producing appliance.
Also, the water heater must be located and/or protect
ed so it is not subject to physical damage by a moving
vehicle.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.
WARNING
Minimum clearances between the water heater and com
bustible construction are 1" at the sides and rear, 4" at the
front, and 6" from the vent pipe. Clearance from the top of the
jacket is 18" on most models. Note that a lesser dimension may
be allowed on some models. Refer to the label on the water
heater adjacent to the gas control valve on all clearances.
U"MAX.
VENTILATION
open
I
ngs
O
f
6“ MIN.
6> MIN.
1" MIN.
TOP VIEW
OF CLOSET
WITHOUT DOOR
MIN.
4” MIN.
12“ MAX.
TOP VIEW ^
OF CLOSET
WITH DOOR
FRONT VIEW
OF DOOR
Figure 1
AIR DUCT
WARNING
A gas water heater cannot operate properly without the cor
rect amount of air for combustion. Do not install in a confined
area such as a closet, unless you provide air as shown in
Figures 1-5. Never obstruct the flow of ventilation air. If you
have any doubts or questions at ail, call your gas company or
Sears Service Center. Failure to provide the proper amount of
combustion air can result in a fire or explosion and can cause
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
WARNING
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry clean
ing equipment, if is imperative that the water heater or water
heaters be installed so that combustion and ventilation air be
taken from outside these areas. Refer to the "Locating The New
Water Heater" section of this manual and also the latest edition
of the National Fuel Gas Code, ANSI Z223.1, also referred to as
NFPA 54 for specifics provided concerning air required.