Cooper-Atkins 93025 User Manual
Page 4

4
5
35025 BATTERY REPLACEMENT
1) Turn battery doorknob counter-clockwise until
rotation stops. The arrow on battery door knob will
point towards unlock icon.
2) Pull battery doorknob to remove battery door
assembly. Remove batteries.
3) Referring to battery polarity drawing on rear label,
install (2) AAA alkaline batteries as shown.
4) To install battery door assembly, ensure that battery
doorknob is turned fully counter-clockwise and arrow
on battery door is pointed towards unlock icon. Push
inward on battery door assembly until battery doorknob
is seated against housing. Rotate battery doorknob
clockwise until rotation stops. The arrow on battery
doorknob will point towards lock icon.
TURN COUNTER-CLOCKWISE TO UNLOCK
TURN CLOCKWISE TO LOCK
SYSCAL 35025 THERMOCOUPLE
OPERATING INSTRUCTIONS
5) The resolution default setting is tenth degree. To
change resolution to whole degree, press and hold
key and then press key.
6) Press key to turn on backlight. When pressed,
the backlight will remain on for 5 seconds and
automatically turn off.
NOTE: USE OF BACKLIGHT WILL
SIGNIFICANTLY DECREASE BATTERY
LIFE DUE TO INCREASED POWER
REQUIRED FOR BACKLIGHT OPERATION
7) The instrument has a “HOLD” feature to capture the
current temperature reading on the display. To activate
the hold feature, press and release the key. The
current temperature reading will flash on the display
and the hold icon will appear at top of display. Press
the key again to return to STANDARD
TEMPERATURE MODE.
Press to turn instrument ON or OFF. When
used in combination with SHIFT key, enables
or disables AUTO-OFF feature.
Press to select FAHRENHEIT or CELSIUS
temperature scale. When used in combination
with SHIFT key, selects tenth degree or whole
degree resolution.
Press to “FREEZE” current temperature
reading on display. SHIFT function provides
secondary user settings with other keys as
noted.
Press to turn on BACKLIGHT for viewing
temperatures in low lighting conditions.
When pressed, BACKLIGHT will remain on
for 5 seconds.
OPERATION:
1) Observing correct polarity, insert thermocouple probe
into connector on top of instrument.
2) Press key to turn instrument on.
3) Default temperature scale is Fahrenheit. To change
temperature scale, press key. (NOTE: Display
will toggle between “F” and “C” icons on right
side of display with each press of the key).
4) The instrument has an AUTO-OFF feature that will turn
off unit after 10 minutes of non-keypad activity to
conserve battery life. To manually turn instrument off,
press and hold key momentarily. To disable
AUTO-OFF feature, press and hold key and then
press key. (NOTE: “AUTO” icon at top of display
will appear when AUTO-OFF feature is active).
(0.1/1)
BATTERY REPLACEMENT: