Winco DSE7000 Quick Start Guide User Manual
Page 11

DSE Model 7000 Series Quick Start Guide
Part No. 057-101 7000 Series Quick Start Guide ISSUE 1 14/04/2009 JR
11
3.4.1 INSTRUMENT PAGE CONTENT
Engine
•
Engine Speed
•
Oil Pressure
•
Coolant Temperature
•
Engine Battery Volts
•
Run Time
•
Oil Temperature*
•
Coolant Pressure*
•
Inlet Temperature*
•
Exhaust Temperature*
•
Fuel Temperature*
•
Turbo Pressure
•
Fuel Pressure*
•
Fuel Consumption*
•
Fuel Used*
•
Fuel Level*
•
Auxiliary Sensors (If fitted and configured)
•
Engine Maintenance Due (If configured)
•
Engine ECU Link*
*When connected to suitably configured and compatible engine ECU. For details of supported engines see
‘Electronic Engines and DSE wiring’ (DSE Part number 057-004)
Generator
•
Generator Voltage (ph-N)
•
Generator Voltage (ph-ph)
•
Generator Frequency
•
Generator Current
•
Generator Earth Current
•
Generator Load (kW)
•
Generator Load (kVA)
•
Generator Power Factor
•
Generator Load (kVAr)
•
Generator Load (kWh, kVAh, kVArh)
•
Generator Phase Sequence
Mains (DSE7220/DSE7320 only)
•
Mains Voltage (ph-N)
•
Mains Voltage (ph-ph)
•
Mains Frequency
About
•
Module Type
•
Application Version
•
USB ID – unique identifier for PC USB connection
•
Analogue Measurements Version
•
Firmware Update Bootloader Version