beautypg.com

Testing policy, Introduction and description – Winco ULPSS90/B WITH DSE 7110 CONTROL (2011) User Manual

Page 4

background image

Page 2

1270-10 REV B

60706-213

TESTING POLICY:

Before any generator is shipped from the factory, it is fully
checked for performance. The generator is loaded to its full
capacity, and the voltage, current, and frequency are carefully
checked.

Rated output of generators is based on engineering tests of
typical units, and is subject to, and limited by, the temperature,
altitude, fuel, and other conditions specified by the manufacturer
of the applicable engines.

INTRODUCTION AND
DESCRIPTION

With the addition of an Automatic Transfer Switch this packaged
standby system includes all items necessary for a completely
automatic standby power system..

DESCRIPTION

This package power system is designed to automatically provide
standby power to unattended loads during electrical outages.
Upon an interruption of normal electrical service this package
power system's electrical control circuits will automatically start
the engine. The generator will produce electrical power and the
Automatic Transfer Switch (A.T.S.) will automatically transfer the
electrical loads to the engine-generator set. Upon restoration of
normal electrical service the A.T.S. will sense return of the normal
commercial power and retransfer the load back to normal
commercial power source. The engine control circuits shut off the
run signal to the engine generator set.

These package power systems consist of two major components:

1) AUTOMATIC TRANSFER SWITCH (UL LISTED)

The Automatic Transfer Switches (A.T.S.) is a wall mount switch
designed for inside installation. A electronic exerciser circuit is
installed in the A.T.S. as standard equipment. The A.T.S. also
contains the power failure sensing circuitry necessary to send a
start/stop signal to the engine generator set. The following is a list
of recommended A.T.S. sizes for each model. Outside switches
as well as additional sizes are available, consult your sales rep
for additional information.

RECOMMENDED

MODEL

VOLTAGE

ATS AMPERAGE

PSS60-3

120/240

400

PSS60-4

120/208

400

PSS60-17

120/240

200

PSS60-18

277/480

100

PSS90-3

120/240

400

PSS90-4

120/208

400

PSS90-17

120/240

400

PSS90-18

277/480

200

Additional optional A.T.S. sizes are available to meet specific
needs. Contact your local WINCO dealer or the WINCO Sales
Department for a quote.

2) ENGINE/GENERATOR

PSS60LS- The engine generator set consists of a GM 5.7L, V-8
industrial, liquid cooled engine equipped to run on L.P./N.G. fuel.
The engine operates at 1800 rpm and frequency regulation is
maintained by the electronic governor within .5 cycles variation,
from no load to rated load. The 60,000 watt (60kW) generator is
a single bearing, direct drive, rotating field design. The generator
is connected to the engine flywheel via flexible drive disks. The
engine generator is mounted in a weather proof enclosure for
outside installation. Connection boxes are provided to all
customer connections (both AC output and DC control). A
customer supplied 12 Volt, 650 CCA (BCI group 24) battery is
required to complete the installation. Engine operation is con-
trolled by a Digital Genset Controller (DGC) mounted in the
engine generator enclosure.

PSS90LS - The engine generator set consists of a GM 5.7L,
Turbocharged/Aftercooled V-8 industrial, liquid cooled engine
equipped to run on L.P./N.G. fuel. The engine operates at 1800
rpm and frequency regulation is maintained by the engine
governor within .5 cycles variation, no load to rated load. The
90,000 watt (90kW) generator is a single bearing, direct drive,
rotating field design. The generator is connected to the engine
flywheel via flexible drive disks. The engine generator is mounted
in a weather proof enclosure for outside installation. Connection
boxes are provided to all customer connections (both AC output
and DC control). A customer supplied 12 Volt, 650 CCA (BCI
group 24) battery is required to complete the installation. Engine
operation is controlled by a Digital Genset Controller (DGC)
mounted in the engine generator enclosure.

** NOTICE **

These units will automatically transfer if a power outage occurs
while running in an exercise mode.

ENGINE CONTROL MODULE (DSE 7110 Series)

The DSE 7110 Series control modules provide integrated engine
and generator set control, protection and metering in a single
package. Microprocessor based technology allows for exact
measurement, set point adjustment, and timing functions. Front
panel controls and indicators enable quick and simple operation.

Fully configurable via PC software, allows units to be easily
customized for each application. Includes selected front panel
programming for on site changes. A wide temperature-range
liquid crystal display (132 x 64) with backlighting can be viewed
under a wide range of ambient light and temperature conditions.

FEATURES

DSE 7110 Control Modules have the following features:

¨ Local and Remote Generator Control
¨ Engine and Generator Protection
¨ CAN Bus compatible
¨ Programmable Logic
¨ Five-key Menu Navigation
¨ Engine Exercise Mode

This manual is related to the following products: