Winco CSADL6000IE/C User Manual
Page 2
USING THIS MANUAL
Congratulations on your choice of a DYNA generator
set. You have selected a high-quality, precision-
engineered generator set designed and tested to give
you years of satisfactory portable service.
To get the best performance from your new engine
generator set, it is important that you carefully read and
follow the operating instructions in this manual.
Should you experience a problem please follow the
“Things To Check” near the end of this manual. The
warranty listed in this manual describes what you can
expect from DYNA should you need service assistance
in the future.
PROPER USE AND INSTALLATION
You must be sure your new engine generator set is:
* Properly serviced before starting
* Operated in a well ventilated area
* Operated so that exhaust gases are dispersed safely
* Wired by a qualified electrician
* Operated only for its designed purposes
* Used only by operators who understand its operation
* Properly maintained
TABLE OF CONTENTS
INTRODUCTION
i
UNIT SPECIFICATIONS
i
GUIDE TO PRODUCT SAFETY
1
BASIC INFORMATION
Intended Uses
2
Restricted Uses
2
Unit Capabilities
2
PREPARING THE UNIT
Unpacking the unit
3
Unit Preparation
3
Low Oil Level Shutdown System
3
STARTING INSTRUCTIONS
Initial Starting
4
Starting
4
Starting Hints
4
Stopping And Storage
4
Operating Speed
5
Connecting The Loads
5
OPERATOR CARE AND MAINTENANCE
Engine Care
6
Generator Care
6
Cleaning
6
Troubleshooting - Things To Check BEFORE
You Call For Service
7
Generator Parts List
7
Complete Unit Parts List
8
Receptacle Panel Parts List
9
Wiring Diagram
10
WARRANTY
10
Read and understand all instructions in the manual before starting and
operating the generator set.
COPY YOUR MODEL AND SERIAL
NUMBER HERE
No other DYNA generator has the same serial number
as yours. It is important that you record the number and
other vital information here. If you should ever need to
contact us on this unit it will help us to respond to your
needs faster.
MODEL
_____________________________
SERIAL NUMBER _____________________________
PURCHASE DATE_____________________________
DEALER_____________________________________
UNIT SPECIFICATIONS
GENERATOR
Surge Watts
6000
Continuous Watts
5500
Volts
120/240
Amps
22.9
Receptacles
Nema 5-20R (120V)
2 (20A Duplex)
Nema L14-30R (120/240V)
1 (30A Twistlock)
ENGINE
Briggs & Stratton Intek
Electric Start
Recoil Start
Model Number
210417
210412
Type & Code
0134-E1
0070-E1
Fuel Capacity
4.5 Gallons
Run Time - Full Load
6.5 Hours
Run Time - Half Load
10.2 Hours
Starting System
Electric/Recoil
Recoil
Stop System
Key Switch
Panel Switch
COMPLETE UNIT
Weight
153 lbs.
150 lbs.
Dimensions LxWxH
26.25" X 17.5" X 21.4"