Specifications, Testing policy, Intended uses – Winco W6010DE/G User Manual
Page 4: Restricted uses

4
4150-00
60706-245
SPECIFICATIONS
MODEL W6010DE/G
Generator
Surge Watts
6000
Continuous Watts 5500
Volts 120/240
AMPs @ 240 Volts 22.9
AMPs @ 120 Volts 45.8
Engine
Size 9.9
HP
Model Yanmar
L100V
Type -
See Engine Shroud For
Fuel Capacity-
7 gal
Fuel Consumption .7 gal/hr
Starting System 12 Volt Electric/Key
Muffl er
Low Tone
Stop System
Key
Complete Unit
Weight (dry)
288 LBS
Dimensions LxWxH 32 X 22 X 23
Owner Must Provide
Fuel #2
Diesel
Oil Type
10W-30 CD or higher
for -4F to 80F
See engine manual for additional oil information.
Oil Capacity
1.7 Qts (1.6 L)
TESTING POLICY
Before any generator is shipped from the factory, it is fully
checked for performance. The generator is loaded to its
full capacity, and the voltage, current and frequency are
carefully checked.
Rated output of generator is based on engineering tests of
typical units, and is subject to, and limited by, the tempera-
ture, altitude, fuel, and other conditions specifi ed by the
manufacturer of the applicable engines.
INTENDED USES
This engine generator set has been designed primarily for
portable heavy duty commercial use. Both 120 volt and
240 volt receptacles are provided in the control panel to
plug in your loads (lights, portable tools, and small appli-
ances).
This portable unit requires large quantities of fresh air for
cooling the engine and generator. For safety, long life and
adequate performance, these units should never be run in
small compartments without positive fresh air fl ow.
RESTRICTED USES
DO NOT remove from the cradle assembly. Removal of
the generator from the cradle assembly may cause exces-
sive vibration and damage to the engine-generator set.
DO NOT install and operate this generator in a small
compartment., i.e. generator compartments of vehicles,
motor homes or travel trailers. These compartments will
not allow enough free fl ow of fresh air to reach the engine
generator set for cooling and will cause the unit to over-
heat, damaging both the engine and generator. Small
compartments will also develop hot spots where there is
very little air fl ow and may cause a fi re.
PLEASE NOTE There are 3rd party companies making
enclosures for generators that have been properly engi-
neered. The use of these 3rd party enclosures is accept-
able as long as they have been certifi ed and meet current
code.
DO NOT attempt to operate at 50 cycles. These units
are designed and governed to operate at 60 cycles only.