beautypg.com

Fig. 7, O. appendix for basement installations – Water Factory Systems SQC Pro User Manual

Page 10

background image

O. APPENDIX FOR BASEMENT INSTALLATIONS

The following variations are generally required for
basement installations:

INSTALL THE DRAIN CONNECTION

For basement installations, the drain saddle is generally

not used. Instead, the RO reject line (SFC tubing) is routed so
that it drains into a laundry sink, floor drain, or standpipe
through an approved air gap.

MOUNT THE FAUCET

If you choose to use the air gap faucet included with the

RO system, follow the faucet installation instructions given ear-
lier in this manual. Do not hook up any air gap tubing to the
faucet since an alternate air gap will be used elsewhere in the
drain line.

If you choose to use the optional non-air gap faucet,

follow the instructions below.
A) Familiarize yourself with all of the components shown in

the diagram of the non-air gap faucet. (See Fig. 2)

B)

Install only the chrome base plate and rubber sealing washer
onto the threaded nipple. (Plumbers' putty may be used in
place of the sealing washer for a neater appearance.)

C)

Feed the threaded nipple through the sink/counter-
top mounting hole (a 9/16" hole is adequate).

D)

From underneath the sink/countertop, install the
plastic bottom washer, flat washer, star washer,
and hex nut onto the threaded nipple. Hand tighten
the hex nut until the faucet feels snug.

E)

After rechecking the faucet orientation, tighten
the hex nut with at 9/16" wrench until the faucet
feels secure.

F) From above the sink, make any minor orientation

corrections by turning the faucet on its "flats" with a
padded adjustable wrench. Use care so as not to
mar the chrome finish.

INSTALL THE PURIFICATION ASSEMBLY AND THE
STORAGE TANK

The purification assembly is generally mounted to

the basement wall (using wall anchors) or to the wood
ceiling supports. To mount the purification assembly,
keep the bracket level and mark the location of the
mounting holes. Install wall anchors and/or mounting
screws as required. Leave the screw heads protruding
to allow the bracket mounting slots to slide over them.
(See Fig. 7)

The tank may be oriented either vertically or hori-

zontally and can be placed on a shelf, on the floor, or
suspended from the ceiling supports using brackets.

An effort should be made to minimize the distance

between the tank and purification assembly in order to
ensure an adequate flow rate to the faucet. For hori-
zontal positioning on a shelf or floor, carefully detach
the tank base from the bottom of tank and use it as a
cradle.

MAKE THE TUBING CONNECTIONS
1)

A proper length of the 1/4" orange feedwater tubing
should already have been connected to the feed-
water tapping valve. Route it through the large
opening in the bottom of the metal bracket and loop
it back to the "FEED" connection on the purification
assembly.

2)

Attach the 1/4” x 3/8” union to 1/4” blue tubing on faucet.

3)

Connect a longer length of 3/8" blue tubing (not included)
to the faucet adapter. Route the tubing through the floor to
the location of the purification assembly. Remove the
existing 3/8” blue tubing from the purification assembly.
Route the other end of the longer length of 3/8” blue tubing
through the large opening in the bottom of the metal
bracket and connect it to the “FAUCET” connection on the
purification assembly.

NOTE:

Instead of removing the existing 3/8" blue tubing from

the purification assembly, a 3/8" connector fitting can be used
to join the tubing from the faucet with the tubing from the purifi-
cation assembly.

4)

Route the 3/8" yellow tubing from the purification assembly
to the storage tank.

5)

Route 1/4" tubing from an appropriate drain connection
(e.g. laundry sink, floor drain, standpipe) to the location of
the purification assembly. An air gap must be provided
between the outlet and the drain connection.

6)

Connect the red SFC tubing from the purification assembly
to the 14" tubing from the drain connection using the 1/4"
connector fitting on the end of the SFC tubing.

10

Faucet without

Air Gap

3/8” Blue Tubing*

For refrigerator ice-

maker or water dis-

penser hookup, tee

into tubing

Feedwater Tapping

Valve

Cold Water

Supply Pipe

1/4” Orange

Tubing

3/8” Yellow

Tubing*

Storage

Tank **

1/4” green tubing

Air Gap Device

(e.g. Gap-A-Flow)

Laundry Sink,

Standpipe or

Floor Drain

Storage Tank

Valve

Red SFC Tubing

* For best flow, keep the tubing as short as possible

** Mount the storage tank on a shelf or strap it between two floor joists

Purification Assembly

110/60 (220/50) Electrical Connection

Necessary at This Location

Fig. 7