beautypg.com

VACUUBRAND MV 10 NT User Manual

Page 17

background image

page 17 of 70

of such substances from the pump outlet, install an

appropriate collecting and disposal system and take

protective action for pump and environment.

You must take suitable precautions to prevent any for-

mation of explosive mixtures in the pump chamber or

at the outlet of the pump. In case, e.g., of a diaphragm

failure, mechanically generated sparks, hot surfaces

or static electricity may ignite these mixtures. Use inert

gas for venting, if necessary.

Drain appropriately or otherwise remove any poten-

tially explosive mixtures at the outlet of the pump, or

dilute them to non-explosive concentrations.

Never operate this pump if it has a damaged cord or

plug.

+

If the pump is not working properly, has been dropped

or has fallen into water, contact your pump service pro-

vider.

+

Prevent any part of the human body from coming into

contact with vacuum.

+

Always provide a free and pressureless exhaust outlet

to avoid damage to pump valves and risk of bursting.

+

Attention: Due to clogging of the silencer an internal

overpressure may build up, which may damage bear-

ings, diaphragms and valves. Preferably use the hose

nozzle as outlet and make sure that the exhaust pipe-

line cannot become blocked.

+

Comply with applicable regulations when disposing of

chemicals. Take into consideration that chemicals may

be contaminated. Take adequate precautions to pro-

tect people from the effects of dangerous substances

(chemicals, thermal decomposition products of fluoro-

elastomers). Use appropriate protective clothing and

safety goggles.

This manual is related to the following products: