Warning: The LP Hose and Regulator Assembly should be a Type 1 Connection

and set at 11” of Water Column.

LP Hose with regulator

3

.

Testing

3-1) Make sure the regulator has been properly connected, replaced for LP Gas

3-2) Check for leaks.

3-3) NEVER USE THE UNIT WITHOUT FIRST LEAK TESTING THE GAS

CONNECTION.

a) Prepare a leak testing solution of sudsy water by mixing in a spray

bottle with half liquid soap and half water.

b) Confirm that all control knobs are in the “OFF” position.

c) Turn the main gas valve supply “ON”.

d) Apply leak testing solution by spraying on the pipe joints, fittings, and

hose.

e) A gas leak is detected if;

i.

there is a faint gas smell and/or

ii.

growing bubbles appear on any of the connection points

and/or hose. DO NOT attempt to turn on the burners and

IMMEDIATELY turn off the gas supply valve.

f) When there is a gas leak, call a qualified service technician. DO NOT

use the unit until the leak is corrected.

3-4) Fill up the Conversion Label. Next, paste it next to the original Serial Plate.

3-5) The conversion is complete and the unit is ready for installation. Refer back to

the Installation Manual.