Twin Eagles TEVH60-B User Manual
Ventilation hoods

Page 1 of 8 11503.00 Rev C
INSTALLATION INSTRUCTIONS
MODELS: TEVH36-B, TEVH48-B & TEVH60-B
Ventilation Hoods
PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING.
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT:
Save these Instructions for the Local Electrical Inspector's use.
INSTALLER:
Please leave these Installation Instructions with this unit for owner.
OWNER:
Please retain these Instructions for future reference
IMPORTANT SAFETY INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
HOODS SHOULD BE INSTALLED WITH VENTILATORS APPROVED FOR USE WITH THE HOOD.
SEE TABLE – 1 ON THIS PAGE FOR APPROVED VENTILATORS.
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO
PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and Electrical
Wiring Must Be Done By Qualified
Person(s) In Accordance With All
Applicable Codes & Standards.
Including Fire-Rated Construction.
“WARNING” To Reduce The Risk
Of Fire, Use Only Metal Duct Work.
B.
Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent
backdrafting. Follow the heating
equipment manufactures guideline
and safety standard such as those
published by the National Fire
Protection Association (NFPA) and
the American Society for Heating,
Refrigeration and Air Conditioning
Engineers
(ASHRAE), and the local
code authorities.
C. When cutting or drilling into wall or
ceiling, do not damage electrical
wiring and other hidden utilities.
D. Ducted fans must always be vented to
the outdoors.
E. Before Servicing or Cleaning Unit,
Switch Power off At Service Panel
And Lock Service Disconnecting
Means to Prevent Power From Being
Switched On Accidentally. When The
Service Disconnecting Means Cannot
be Locked, securely Fasten A
Prominent Warning Device, Such As
A Tag, To The Service Panel
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO
DUCT AIR OUTSIDE FOR DUCTED FANS – DO NOT VENT EXHAUST AIR INTO SPACE WITHIN
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES.
Read this instruction completely before starting installation. Planning the complete installation before starting any work
is highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements,
and adequacy of mounting surfaces.
DUCTING: Use a minimum 8" round duct for TEVI-060I installations. Use a minimum 10" round duct for TEVI-120I and
TEVE-150E installations. See Page – 2 for Transition (Purchased Separately) Recommendations.
TABLE - 1
Use model TEVI-060I or
TEVI-120I for internal ventilator.
Use TEVE-150E for remote
ventilator
This hood series has been designed to be used with the ventilators shown in
Table – 1. Before cutting into cabinets, it is necessary to confirm that the
correct ventilator is being used. Your dealer should have reviewed your needs
prior to your purchase. Be sure you have the correct ventilation system.
CAUTION: To Reduce The Risk Of Fire And Electrical Shock, Install This
Ventilation Hood Only With Blowers Manufactured By Twin Eagles.
13231 East 166
th
St.
Cerritos, CA 90703
Phone (562) 802-3488
Fax (562) 802-3391
www.TwinEaglesBBQ.com