6. Interface for MP-20 Mini Printer
6.1 Working Modes
Name Description
Character Mode (default):
Prints one line of characters whenever a “carriage
return” is received from serial port.
Barcode Mode:
Prints one line of barcodes whenever “carriage return” is
received from serial port.
Command-Line Mode:
Accepts predefined command lines from serial port.
Test Page Mode:
Operates a batch of pre-input command lines to print a
featured label.
Configuration
Mode:
Restores system default settings including header
contents.
6.2 Accepted Commands in Command-Line Mode: (See Appendix B for
examples)
Ax,y,rotate,font,reverse,”string”
Print one line of characters
Bx,y,rotate,height,withAscii,”string”
Print one barcode of characters
Dden
Set default density
Ffont
Set default font
N
Clear image buffer
Qheight,width
Set default label size
Lx,y,width,height
Print a rectangular bar
Xx,y,x1,y1,linewidth
Print a rectangular box
Pncp
Print copies of image buffer
Arguments:
x
start position on x axle
y
start position on y axle
rotate line
orientation
font font
used
reverse
if reverse printed. 0: No; 1: Yes.
string characters
printed
height
size on y direction
withAscii
if readable characters printed.
0: No; 1: Yes.
den
number of density. 0 – 500.
width
size on x direction
x1
end position on x axle
y1
end position on y axle
linewidth
width of line used
ncp
number of copies printed