Triner Scale RAVAS-310 User Manual
Page 27

27
25
Dataprotocol comport 1
0-4
0
0=PC bi-directional command structure
1=not used
2=Remote display continuously
3=Printer (without date/time/switched supply)
4=not used
26
Number of linefeeds comport
1
0-9
0
27-29
Not used
30
Baudrate comport 2
600-1200-2400-4800-9600-19200
9600
31
Databits comport 2
7-8
8
32
Parity comport 2
none/odd/even
none
33
Stopbits comport 2
1-2
1
34
Not used
35
Dataprotocol comport 2
0-4
3
0=PC bi-directional command structure
1=not used
2=Remote display continuously
3=Printer (without date/time/switched supply)
4=not used
36
Number of linefeeds comport
2
0-9
5
37
Printout form
0-1
0
0=standard 1=total
38
Printout format time/date
European format dd/mm/yy hh:mm
USA
USA format mm/dd/yy hh:mm
39
Not used
40
Level switch
0=not used 1=N.C. 2=N.O.
0
41
Delay trigger time level switch
0-10 sec.
3
42
Not used
43-49
Not used
50
Battery used
12VDC 6 VDC
12v
51
Low Bat switch off time
0-99 mins
2
0=not switched off
52
Auto shut off time if not used
0-99 mins
15
0= always on
53
Not used
54
Peak hold time
0-7
4
55
threshold value
9999kg/lb
200
56-89
Not used
90
Reset to default parameter
If parameter 01 was on 1 it will default to the
setting without altering
EU settings. If P_01 =2 the US settings will be
calibration parameters
defaulted. New delivered boards will have
EU settings.