beautypg.com

Setting the arc function, Outline of the arc function settings – Toa M-633D User Manual

Page 11

background image

11

9. SETTING THE ARC FUNCTION

9.1. What is the Automatic Resonance Control (ARC) Function?

It is a function that automatically creates a sound field compensation filter (ARC filter) to improve sound

clarity by measuring the inherent acoustic characteristics in architectural space.

9.2. Outline of the ARC Function Settings

The ARC function automatically creates an ARC filter, thereby reproducing highly clear output sound.

9.2.1. Enabling the ARC function (See p. 13 for details.)

Note

Before operating the ARC function, check that sound is actually output from the speakers after installation

and connection completion.

Select with the Assignment switches the output channel to which the ARC filter is to be set, hold down the

ARC switch for 3 seconds, then release it when the ARC operation indicator begins to flash.

The ARC measurement starts.

The ARC filter is set when the measurement has finished, enabling the ARC function. (The ARC operation

indicator lights.)

Note: To stop measurement partway, press the ARC switch again.

Flashing during

measurement

Measurement in progress

Measurement stops.

Press

ARC

ARC

ARC

ARC

Lit

ARC

Unlit

Hold down for

3 seconds.

ARC

Release when the indicator

begins to flash.

9.2.2. Disabling the ARC function (See p. 20 for details.)

Holding down the ARC switch for 8 seconds or more with all the 3 assignment switches of the MONO 1 in

OFF mode (unpressed state) causes the ARC operation indicator to flash. Then it goes off, disabling the ARC

function.

Flashing

ARC

ARC

ARC

Unlit

ARC

Lit

Hold down for

8 seconds or more.

ARC

Release when

the indicator goes off.

3 – 8 seconds

0 – 3 seconds

After 8 seconds