Symptom
Cause and Points to Check
Remedy
Indicator on the
microphone goes out
during speech.
Mic-Off function set to ON.
Disable the Mic-Off function if a long
pause is made during speech.
Microphone indicator
flashes.
Battery voltage has dropped below a
marginal level.
Replace the battery with a fully charged
one.
Chime does not
sound when the
Priority Speech key is
pressed.
Central unit’s rear panel-mounted
Priority Chime volume control is set to
the minimum volume position.
Adjust the volume control to an
appropriate level.
The Priority chime mute switch in the
Chairman unit’s bottom is set to ON.
Set the Priority chime mute switch to
OFF.
Mic-Off function does
not work.
High background noise level generated
by such equipment as air conditioners.
In areas where the background noise
level is high, the Mic-Off function may
not work.
Reposition in a low-noise location or
turn off the Mic-Off function.
Battery can be used
only for a short period
of time.
Not fully charged.
Charging is completed within 5 hours.
Note: Fully charged batteries can be
used for up to 10 hours.
(Refer to the separate Installation
manual.)
Battery is approaching the end of its life. Use a brand-new battery.
Note:
Battery can be recharged
almost 300 times.
10.2. Wired Chairman Unit TS-911/811 and Wired Delegate Unit TS-912/812
Symptom
Cause and Points to Check
Remedy
Cannot turn ON power. Both the Central unit and the Expansion
unit are not powered up.
Switch on the Central unit’s power and
power up the Expansion unit through
the AC adapter.
They are not connected properly.
Check all connections. (Refer to the
separate Installation manual.)
No sound output
from the speaker or
headphone.
Monitor Selector switch not correctly
set. (TS-911/912 only)
Set the switch to the position where
sound can be heard.
Central unit’s Microphone Mix/Cut
switch not correctly set.
Monitor volume control not correctly
adjusted.
Adjust the volume to an appropriate
level.
Headphone plug not fully inserted.
Insert the headphone plug fully into the
jack.
Cannot initiate speech. Central Unit’s rear panel-mounted Short
Circuit indicator remains lit.
Check the cable connected to the
Central Unit’s Infrared Transmitter/
Receiver unit I/O terminals.
Live Status indicator on the Infrared
Transmitter/Receiver unit remains dark.