LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label found on the unit.
2. Make sure the switch (Not the pilot control knob) is turned to "OFF". (See Figure 3)
3. Turn off all electrical power to the unit.
4. Push in pilot control knob slightly and turn clockwise to "OFF".
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas: STOP! Follow B on the safety Information label.

If you don't smell gas continue on to the next step.

6. The pilot is located by the main burner.
7. Push in the pilot control knob slightly and turn counter-clockwise to "Pilot".
8. Hold the pilot control knob in and push the piezo button (located on the left side of the unit)

until the pilot flame appears.

9. Continue holding the pilot control knob for up to one (1) minute before releasing. The knob will

pop back out upon release. Pilot should remain lit. If it goes out repeat steps 5 through 8.

If knob does not pop out when release, stop and immediately call your service technician.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service

technician.

10. Push in the pilot control knob and turn counter-clockwise to "ON".
11.

It will take 2 - 3 minutes for thermocouple to heat up and flame to appear.

12. This valve is equipped with a HI/LO feature. Set unit to desired flame height. The valve is also equipped

with a safety lockout feature that will prevent the relighting of the pilot after it is extinguished. You
must wait one (1) minute for valve to reset itself before relighting the pilot.

13. Then move switch to remote. You will then be able to switch the unit "ON" or "OFF" using the remote.
14. To operate unit with remote:

a. Make sure switch is turned to "REMOTE"
b. Make sure

pilot control knob is switched to "ON"

c. Press button once to turn unit "ON". You will hear a soft beep than the flame will appear.
d. To turn the unit "OFF". Press the button on the remote once after five (5) seconds the flame

will disappear and the unit will turn off (NOTE: the pilot light will remain on).

Page 8

MATCH LIGHTING INSTRUCTIONS

If the pilot cannot be ignited with the piezo, it can be manually lit with a match. Follow steps 2 through 8. Push
the pilot control knob in fully and hold it in. Immediately light the pilot with a match. Continue to hold the pilot con-
trol knob in for about one (1) minute. After one (1) minute, release the knob and it will pop back out. The pilot
should remain lit. If it goes out, repeat steps 2 through 8.

If the control knob does not pop out when released, STOP and immediately call your service

technician or gas supplier.

If the pilot will not stay lit after several tries, turn the pilot control knob clockwise to "OFF" and

call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1. Turn the switch to "OFF".
2. Push in the pilot control slightly and turn clockwise to "OFF". DO NOT FORCE.

HI/LO

Setting

Make sure

switch is turned

to "OFF" when

lighting; and

"REMOTE" to

use the remote.

Pilot

control

knob

Figure 3