Replacement parts, Performance data, Ct-2r cartridge – Culligan CT-2 User Manual
Page 3
3
Technical Support: 1-800-645-5426 Mon–Fri., 7:30 AM–5 PM CST
Replacement Parts
Replacement Filter Cartridges:
• CT-2R Filter Cartridge for CT-2 Filter (155158)
Filter Parts:
1. Top of Housing
2. Replacement Filter Cartridge
(see “Replacement Cartridges”above)
3. Gasket (143340)*
4. Base of Filter Housing
5. DV-2 Diverter Valve / Aerator (158408)*
6. Adapters (144249)*
* Available replacement parts.
Please contact Culligan Consumer
Services at 1-888-777-7962.
Suggested Retail Price for Replacement Filter Cartridges:
CT-2R: $20.00
NOTE: Price subject to change. Contact your local retailer or call: 1-888-777-7962
for current replacement cartridge pricing.
Performance Data
Important Notice: Read this performance data and compare the capabilities of
this system with your actual water treatment needs. It is recommended that,
before installing a water treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of
the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.
CT-2R Cartridge
Substance
Influent Challenge
Max. Permissible Product
Reduction
Minimum
Average
Concentration
Water Concentration
Requirements
Reduction
Reduction
Standard 42 Aesthetic Effects
Chlorine
2.0 mg/L±10%
≥ 50%
97%
Particulates (0.5– at least 10,000
≥ 85%
96%
<1µm) Class I
particles/mL
Standard 53 Health Effects
Cysts†
Minimum 50,000/L
99.95%
99.99%
99.99%
Turbidity
11 mg/L±1 NTU
0.5 NTU
95.4%
97.4%
Asbestos
10
7
to 10
8
fibers/L>10
99%
99.9%
99.9%
micrometers in length
Lead pH 6.5
0.15 mg/L±10%
0.010 mg/L
99.3%
99.3%
Lead pH 8.5
0.15 mg/L±10%
0.010 mg/L
94.1%
97.6%
Mercury pH 6.5 0.006 mg/L±10%
0.002 mg/L
72.0%
88.5%
Mercury pH 8.5 0.006 mg/L±10%
0.002 mg/L
95.0%
96.7%
Flow Rate=0.5 gpm (1.89 Lpm) Capacity=400 gallons (1514 L) or 4 months
† Based on the use of microspheres or Cryptosporidium parvum oocysts.
Testing was performed under standard laboratory conditions, actual performance may vary.
Test Conditions:
Flow Rate:
0.5 gpm (1.9 Lpm)
Ph:
6.5–8.5
Temperature:
68°F +/- 5°F (20°C +/- 2.5°C)
Operating Requirements
Pressure:
30–125 psi (2.1 – 8.6 bar)
Temperature:
40 –100°F (4.4–38°C)
Turbidity:
5 NTU Max