Using at commands 27 – Solvline MultiModem User Manual
Page 27
Using AT Commands
27
regardless of dial tone existence. This is called „BLIND DIALING‟.
. Parameter : 0 ~ 4
. Default : 4
X0 : Connect message-CONNECT
Dialing - Dialing after waiting for a dial tone.
BUSY tone check - NO
X1 : Connect message-all messages (CONNECT 1200 seconds)
Dialing - Dialing after waiting for a dial tone.
BUSY tone check - NO
X2 : Connect message-all messages
Dialing - Waits for a dial tone.
BUSY tone check - NO
X3 : Connect message-all messages
Waits for the time specified in the dialing- S6 register, and performs dialing.
BUSY tone check-YES
X4 : Connect message-all messages
Dialing- Waits for a dial tone.
BUSY tone check-YES
- ATYn : Enable Long Space Disconnect
If a space signal with 1.6 second or more than 1.6 second is received online, it defines whether
to cut off the line. In addition, if the AT&D2 command is selected or the ATH command is
received, it defines whether to send a space signal with 4 seconds to the modem of the other
party.
. Parameter : 0 ~ 1
. Default : 0
Y0 : long space disconnect prohibition
Y1 : long space enable disconnect permission
- ATZn (n=0.1): Initialization Command
This command performs the initialization process of the modem, and exists in the last part of all
commands. While resetting, it performs initialization with clear serial port buffers and the
specified n profile.
. Parameter : 0 ~ 1
. Default : 0